Introduction
- TH0400, a series of 14 various ranges precision coaxial shunts.
- TH0400 can work in the DC ~ 100 kHz frequency range, converting 1 mA ~ 100 A nominal current into 1 V small current.
- DC ratio accuracy: 20 ppm;AC/DC difference: 20 ppm; phase displacement: 5.
- It is suitable for calibration of AC/DC high current source, current sensor, DC shunt, and other occasions where current needs to be measured precisely.
Features
- The nominal voltage is 1 V, can measure current by directly matching high-precision voltmeters or other measurement instruments.
- For 1 mA, 10 mA and other high resistance current shunts, combine with the model TH0600 to avoid errors caused by wire connection or input impedance drops of digital meters at high frequency.
- Compared to 0.5 V, 0.8 V and other voltage value, the 1V nominal voltage has a higher noise ratio, easier current conversion, faster error calculation, and accords with the 1-2-5 sequence principle of modern measurement.
- Precision components and production processes ensure the resistance value stable, the typical resistance change value is ±5 μΩ/Ω in 1 year, and the maximum resistance change value is ±16 μΩ/Ω in 1 year.
- Good heat dissipation, lower temperature coefficient and self-heating power factor ensure a good stability.
- Small phase displacement between the input current and the sampled voltage, the phase displacement is less than 0.0015 ° even at 1 kHz. This feature is critical for the measurement of non-sinusoidal and wideband signals, applied to analyze power quality and calibrate digital power meters.
- The capacity of loading current and withstanding current impulse is limited, but you can use a set of shunts to obtain a wide range of current measurement.
Specification
Resistance
- Remarks:
①: In the calibration temperature environment, the deviation of the measured resistance value from the nominal resistance value after the rated DC current is applied for ten minutes. Higher precision can be customized according to user requirements, such as: 20μΩ/Ω。
②: The initial deviation of the DC resistance value has included the power coefficient influence error under the nominal current. When measuring other non-nominal currents, additional measurement accuracy should be introduced. The calculation formula is:
Current
Dimension and Weight